Home  /  For the trade

For builders, architects and dealers

System data, North American test results, lead times and ordering terms for dealers, builders, architects and developers.

Trade overview

The numbers, before the sales call.

Everything a dealer, builder or architect needs to qualify Nordhaus for a project: system depths, glass capacity, North American test results, thermal data, lead times and what every quote includes. Send drawings and we return an itemized quote with a drawing for every opening.

12–16 wksProduction lead time from approved drawings, built to order in Europe
±60 psfDesign pressure, Alu 86 aluminum window (North American lab test)
PG-55Wind load rating, Casement 85 profile system, tested to NAFS. Water PG-100 in all configurations
0.13Best window U-value, Btu/h·ft²·°F, 4000 Classic system (0.76 W/m²K)
21 ft 4 inMaximum lift-and-slide system width, Lift 85 (6.50 m), up to 9 ft 2 in high
1,000+Homes supplied by our manufacturing partner since 2015

System performance (profile maker data). Ratings for your order depend on size, configuration and glass. Ask for the documentation your project requires.

Product line

Every system at a glance

Depth is front to back, not visible frame width. US units first, metric in parentheses. Maximum values depend on configuration and cannot always be combined.

SystemMaterialOperationFrame depthGlass capacityKey data
Windows
4000 ClassicVinyl, 5 chambersTilt and turn2 3/4 in (70 mm)Up to 1 5/8 in (41 mm)Uw 0.17 (0.99 W/m²K) standard triple; RC2; up to 45 dB
8000 PassiveVinylTilt and turn3 3/8 in (85 mm)Up to 2 in (51 mm)Uw 0.15 (0.83 W/m²K) standard triple; RC3; up to 48 dB
Casement 85Vinyl, steel reinforcedCasement, awning, picture3 3/8 in (85 mm)Up to 1 13/16 in (46 mm)NAFS tested; PG-55 wind; 1 1/4 in (32 mm) recessed pre-drilled nailing fin
Wood 68 / 78 / 92Pine, oak or merantiBy configuration2.68 / 3.07 / 3.62 inDouble; thicker packages on 78; triple standard on 92Opaque or translucent finishes
HeritageWoodBy configuration2.68 / 3.07 / 3.62 inBy depthDecorative panels, wood caps, period hardware
Clad Classic / Clad ModernWood, aluminum cladBy configuration2.68 / 3.07 / 3.62 inBy depthClassic: restrained exterior. Modern: angular exterior profile
Alu 86Thermally broken aluminumBy configuration3.03 in frame / 3.39 in sashUp to 2.64 inSash to 330.7 lb; ±60.15 psf; Uw from 0.13 (0.72 W/m²K)
Alu 104 PassiveThermally broken aluminumBy configuration3.74 in frame / 4.09 in sashUp to 3.19 inSash to 352.7 lb; two insulation variants
Patio doors
Slide NeoVinylSliding—Up to 2 1/8 in (54 mm)Systems to 19 ft 8 in × 8 ft 2 in (6.0 × 2.5 m); Uf 0.23 (1.3 W/m²K)
S-SlideVinylSliding—By configurationCoordinates with sliding windows
Lift 85VinylLift and slide—By versionTo 21 ft 4 in × 9 ft 2 in (6.50 × 2.80 m); 1 7/8 in (48 mm) low threshold, recessable; Basic, Standard, Premium thermal
S-LiftVinylLift and slide—By configurationLarge-panel alternative to Lift 85
Tilt & SlideVinylTilt and slide—By configurationRoto Patio Alversa hardware; tilt or night ventilation by version
Skyline / Skyline RAluminum, concealed frameSliding, manual or powered—2.05–2.36 inHeights to 13 ft 1 in; 0.98 in center joint; ±50.13 psf (Skyline)
Lift 77AluminumLift and slide—By variant2- and 3-track, selected corners; ±50.13 psf
Lift 82AluminumLift and slide—By variantThree insulation variants
Ultra LiftAluminum, thermally insulatedSliding or lift and slide—By variantLow threshold, monorail, selected 90° corners
Fold 86AluminumBifold, in or out3.39 in frame / 3.03 in panel0.53–2.42 inUp to 8 panels; panels to 9 ft 10 in high and 264.6 lb

System performance (profile maker data). Ratings for your order depend on size, configuration and glass. Ask for the documentation your project requires. U-values in Btu/h·ft²·°F unless noted.

Structural and weather

North American test results

SystemDesign pressureAir infiltrationWater
Alu 86±60.15 psf0.01–0.08 cfm/ft²15.04 psf
Lift 77±50.13 psf0.03–0.18 cfm/ft²10.03 psf
Skyline±50.13 psf0.011 cfm/ft²7.52 psf
Casement 85Up to PG-55NAFS testedPG-100, all configurations

Aluminum results from North American (NCTL) lab tests published by the profile maker. Casement 85 tested to NAFS (AAMA/WDMA/CSA 101/I.S.2/A440).

Thermal, security and sound

Vinyl system performance

4000 Classic8000 PassiveCasement 85
Frame U0.23 (1.3)0.18 (1.0)Up to 0.18
Window U, std triple0.17 (0.99)0.15 (0.83)Up to 0.15
Best window U0.13 (0.76)——
Max glass1 5/8 in (41 mm)2 in (51 mm)1 13/16 in (46 mm)
Burglary resistanceUp to RC2Up to RC3—
Sound reductionUp to 45 dBUp to 48 dB—

U-values in Btu/h·ft²·°F with W/m²K in parentheses; standard triple glazing is Ug 0.6 W/m²K. System values, not NFRC ratings.

Behind the product

Profiles, hardware and certifications

Nordhaus products are fabricated by our manufacturing partner in Europe on established profile systems. The certifications below belong to the profile makers and apply to their systems.

Vinyl profiles

  • aluplast and REHAU profile systems
  • aluplast: 40+ years, customers in 80+ countries, 1,800+ employees
  • RAL quality mark; CE marking monitored by ift Rosenheim
  • TÜV Süd ISO 9001; Passive House Institute
  • Multi-chamber frames, steel reinforcement, multiple seal lines

Aluminum systems

  • Aluprof systems: 70+ years, branches in Europe and the USA
  • ift Rosenheim; Passive House Institute Darmstadt
  • Cradle to Cradle; EPD; ISO
  • Thermally broken profiles; concealed-frame sliding options
  • North American lab test data published

Hardware and build

  • Roto tilt-and-turn hardware with multi-point locking
  • Roto Patio Alversa on Tilt & Slide doors
  • North American crank hardware on Casement 85
  • Built to order in exact sizes; no stock sizes
  • Shapes: arches, circles, ovals and trapezoids by system
Ordering

How an order runs

One contact from first drawings to delivery. Quotes are itemized, and nothing goes into production until you sign the drawings.

StageWhat happensWhat you receiveTiming
01 Send drawingsPlans, elevations or a window schedule, widths and heights in feet and inches. Flag energy, impact or other code requirements up front.Review of systems, glass and finishes for each openingStart of project
02 QuoteEvery opening priced with your sizes, glass, finish and hardware.Itemized quote: product, freight, import charges and delivery, with lead time, payment terms and warrantyAfter drawings
03 Sign the drawingApprove dimensions, opening directions and configuration on the final order drawings.Order drawings for every opening; written production and shipping scheduleBefore production
04 ProductionBuilt to order in Europe and crated for export.Schedule updates12–16 weeks typical
05 DeliveryDelivery scheduled around site access, unloading and storage.Product-specific installation instructions for your crewCoordinated with your site

Dealers

  • Dealer pricing for European windows and patio doors
  • Samples for your showroom
  • Stocking programs for your market
  • Itemized landed cost on every quote
  • Include your company name and the market you serve

Builders and architects

  • Quotes from plans, elevations or schedules
  • Sightline and opening-style comparisons
  • Large glass, corners and custom shapes reviewed from elevations
  • Section drawings and installation requirements
  • Lead time planned against your schedule

Multifamily and developers

  • Pricing from typical unit schedules and quantities
  • Phased delivery planning
  • System options across unit types
  • Submittal package scoped to your project
  • One contact for the whole order

Submittals and documentation

  • Section drawings for the selected configuration
  • Installation requirements, product specific
  • Test and certification documents on request, by system
  • Energy code: give us your climate zone and required U-factor and SHGC at the start. We specify glass to suit and confirm certification status before you order

What to send for a quote

  • Project location and target delivery date
  • Plans, elevations or a window schedule
  • Opening quantities and sizes, noting rough opening or unit size
  • Interior and exterior finishes, glass requirements
  • Code requirements: energy, impact, egress

Send drawings for an itemized quote.

Send the project location, schedule and target delivery date. For dealer inquiries, include your company name and the market you serve.