For builders, architects and dealers
System data, North American test results, lead times and ordering terms for dealers, builders, architects and developers.
The numbers, before the sales call.
Everything a dealer, builder or architect needs to qualify Nordhaus for a project: system depths, glass capacity, North American test results, thermal data, lead times and what every quote includes. Send drawings and we return an itemized quote with a drawing for every opening.
System performance (profile maker data). Ratings for your order depend on size, configuration and glass. Ask for the documentation your project requires.
Every system at a glance
Depth is front to back, not visible frame width. US units first, metric in parentheses. Maximum values depend on configuration and cannot always be combined.
| System | Material | Operation | Frame depth | Glass capacity | Key data |
|---|---|---|---|---|---|
| Windows | |||||
| 4000 Classic | Vinyl, 5 chambers | Tilt and turn | 2 3/4 in (70 mm) | Up to 1 5/8 in (41 mm) | Uw 0.17 (0.99 W/m²K) standard triple; RC2; up to 45 dB |
| 8000 Passive | Vinyl | Tilt and turn | 3 3/8 in (85 mm) | Up to 2 in (51 mm) | Uw 0.15 (0.83 W/m²K) standard triple; RC3; up to 48 dB |
| Casement 85 | Vinyl, steel reinforced | Casement, awning, picture | 3 3/8 in (85 mm) | Up to 1 13/16 in (46 mm) | NAFS tested; PG-55 wind; 1 1/4 in (32 mm) recessed pre-drilled nailing fin |
| Wood 68 / 78 / 92 | Pine, oak or meranti | By configuration | 2.68 / 3.07 / 3.62 in | Double; thicker packages on 78; triple standard on 92 | Opaque or translucent finishes |
| Heritage | Wood | By configuration | 2.68 / 3.07 / 3.62 in | By depth | Decorative panels, wood caps, period hardware |
| Clad Classic / Clad Modern | Wood, aluminum clad | By configuration | 2.68 / 3.07 / 3.62 in | By depth | Classic: restrained exterior. Modern: angular exterior profile |
| Alu 86 | Thermally broken aluminum | By configuration | 3.03 in frame / 3.39 in sash | Up to 2.64 in | Sash to 330.7 lb; ±60.15 psf; Uw from 0.13 (0.72 W/m²K) |
| Alu 104 Passive | Thermally broken aluminum | By configuration | 3.74 in frame / 4.09 in sash | Up to 3.19 in | Sash to 352.7 lb; two insulation variants |
| Patio doors | |||||
| Slide Neo | Vinyl | Sliding | — | Up to 2 1/8 in (54 mm) | Systems to 19 ft 8 in × 8 ft 2 in (6.0 × 2.5 m); Uf 0.23 (1.3 W/m²K) |
| S-Slide | Vinyl | Sliding | — | By configuration | Coordinates with sliding windows |
| Lift 85 | Vinyl | Lift and slide | — | By version | To 21 ft 4 in × 9 ft 2 in (6.50 × 2.80 m); 1 7/8 in (48 mm) low threshold, recessable; Basic, Standard, Premium thermal |
| S-Lift | Vinyl | Lift and slide | — | By configuration | Large-panel alternative to Lift 85 |
| Tilt & Slide | Vinyl | Tilt and slide | — | By configuration | Roto Patio Alversa hardware; tilt or night ventilation by version |
| Skyline / Skyline R | Aluminum, concealed frame | Sliding, manual or powered | — | 2.05–2.36 in | Heights to 13 ft 1 in; 0.98 in center joint; ±50.13 psf (Skyline) |
| Lift 77 | Aluminum | Lift and slide | — | By variant | 2- and 3-track, selected corners; ±50.13 psf |
| Lift 82 | Aluminum | Lift and slide | — | By variant | Three insulation variants |
| Ultra Lift | Aluminum, thermally insulated | Sliding or lift and slide | — | By variant | Low threshold, monorail, selected 90° corners |
| Fold 86 | Aluminum | Bifold, in or out | 3.39 in frame / 3.03 in panel | 0.53–2.42 in | Up to 8 panels; panels to 9 ft 10 in high and 264.6 lb |
System performance (profile maker data). Ratings for your order depend on size, configuration and glass. Ask for the documentation your project requires. U-values in Btu/h·ft²·°F unless noted.
North American test results
| System | Design pressure | Air infiltration | Water |
|---|---|---|---|
| Alu 86 | ±60.15 psf | 0.01–0.08 cfm/ft² | 15.04 psf |
| Lift 77 | ±50.13 psf | 0.03–0.18 cfm/ft² | 10.03 psf |
| Skyline | ±50.13 psf | 0.011 cfm/ft² | 7.52 psf |
| Casement 85 | Up to PG-55 | NAFS tested | PG-100, all configurations |
Aluminum results from North American (NCTL) lab tests published by the profile maker. Casement 85 tested to NAFS (AAMA/WDMA/CSA 101/I.S.2/A440).
Vinyl system performance
| 4000 Classic | 8000 Passive | Casement 85 | |
|---|---|---|---|
| Frame U | 0.23 (1.3) | 0.18 (1.0) | Up to 0.18 |
| Window U, std triple | 0.17 (0.99) | 0.15 (0.83) | Up to 0.15 |
| Best window U | 0.13 (0.76) | — | — |
| Max glass | 1 5/8 in (41 mm) | 2 in (51 mm) | 1 13/16 in (46 mm) |
| Burglary resistance | Up to RC2 | Up to RC3 | — |
| Sound reduction | Up to 45 dB | Up to 48 dB | — |
U-values in Btu/h·ft²·°F with W/m²K in parentheses; standard triple glazing is Ug 0.6 W/m²K. System values, not NFRC ratings.
Profiles, hardware and certifications
Nordhaus products are fabricated by our manufacturing partner in Europe on established profile systems. The certifications below belong to the profile makers and apply to their systems.
Vinyl profiles
- aluplast and REHAU profile systems
- aluplast: 40+ years, customers in 80+ countries, 1,800+ employees
- RAL quality mark; CE marking monitored by ift Rosenheim
- TÜV Süd ISO 9001; Passive House Institute
- Multi-chamber frames, steel reinforcement, multiple seal lines
Aluminum systems
- Aluprof systems: 70+ years, branches in Europe and the USA
- ift Rosenheim; Passive House Institute Darmstadt
- Cradle to Cradle; EPD; ISO
- Thermally broken profiles; concealed-frame sliding options
- North American lab test data published
Hardware and build
- Roto tilt-and-turn hardware with multi-point locking
- Roto Patio Alversa on Tilt & Slide doors
- North American crank hardware on Casement 85
- Built to order in exact sizes; no stock sizes
- Shapes: arches, circles, ovals and trapezoids by system
How an order runs
One contact from first drawings to delivery. Quotes are itemized, and nothing goes into production until you sign the drawings.
| Stage | What happens | What you receive | Timing |
|---|---|---|---|
| 01 Send drawings | Plans, elevations or a window schedule, widths and heights in feet and inches. Flag energy, impact or other code requirements up front. | Review of systems, glass and finishes for each opening | Start of project |
| 02 Quote | Every opening priced with your sizes, glass, finish and hardware. | Itemized quote: product, freight, import charges and delivery, with lead time, payment terms and warranty | After drawings |
| 03 Sign the drawing | Approve dimensions, opening directions and configuration on the final order drawings. | Order drawings for every opening; written production and shipping schedule | Before production |
| 04 Production | Built to order in Europe and crated for export. | Schedule updates | 12–16 weeks typical |
| 05 Delivery | Delivery scheduled around site access, unloading and storage. | Product-specific installation instructions for your crew | Coordinated with your site |
Dealers
- Dealer pricing for European windows and patio doors
- Samples for your showroom
- Stocking programs for your market
- Itemized landed cost on every quote
- Include your company name and the market you serve
Builders and architects
- Quotes from plans, elevations or schedules
- Sightline and opening-style comparisons
- Large glass, corners and custom shapes reviewed from elevations
- Section drawings and installation requirements
- Lead time planned against your schedule
Multifamily and developers
- Pricing from typical unit schedules and quantities
- Phased delivery planning
- System options across unit types
- Submittal package scoped to your project
- One contact for the whole order
Submittals and documentation
- Section drawings for the selected configuration
- Installation requirements, product specific
- Test and certification documents on request, by system
- Energy code: give us your climate zone and required U-factor and SHGC at the start. We specify glass to suit and confirm certification status before you order
What to send for a quote
- Project location and target delivery date
- Plans, elevations or a window schedule
- Opening quantities and sizes, noting rough opening or unit size
- Interior and exterior finishes, glass requirements
- Code requirements: energy, impact, egress
Send drawings for an itemized quote.
Send the project location, schedule and target delivery date. For dealer inquiries, include your company name and the market you serve.